Commit graph

4 commits

Author SHA1 Message Date
a7cc1f502b Fix Windows service mode: it could neither start nor stop.
- Start: WinSW's NetX.out.log/err.log in data\runtime are the same files as
  start_netx.ps1's netx.out.log (case-insensitive) and stay open, so NetX
  could not truncate its log and every start failed. WinSW logs now go to
  data\runtime\service.
- Stop: nothing told the service_run.ps1 supervisor to exit, so it kept
  restarting NetX and WinSW waited forever. stop_netx_app.ps1 writes the
  service.stop flag (-KeepSupervisor for the supervisor's own restarts),
  service_run checks it every second, and runtime_ctl / service_lifecycle
  write it before stopping the service.
- WinSW launched powershell.exe as stop hook never reached the script
  (stuck on inherited std handles); run it via cmd with NUL stdin and output
  to data\runtime\service\stopexec.log. stop_netx_app.ps1 keeps a
  timestamped trace there.

Offline Windows Sandbox: service install -> healthy in 28s, stop in 20s.
Existing service installs need "install service" re-run to pick this up.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-14 00:46:44 +08:00
41ab4921a0 Fix Windows PowerShell parsing on Server 2012: UTF-8 BOM scripts.
Chinese packaging scripts without BOM were misread as ANSI and failed at first-run.
Document that bundled Python 3.13+ needs Server 2016+ / Win10+.

Co-authored-by: Cursor <cursoragent@cursor.com>
2026-10-07 10:53:29 +08:00
d10d47e8f5 Harden Windows packaging: data-root paths, service health, safer updates.
Co-authored-by: Cursor <cursoragent@cursor.com>
2026-10-07 00:12:14 +08:00
b639f01c0f Add Windows service, silent auto-update, and code-signing hooks.
Co-authored-by: Cursor <cursoragent@cursor.com>
2026-10-06 23:53:07 +08:00